Endotoxin Removal from Bench to Process Scale.

April 6, 2017 Andy Davies

Endotoxin or lipopolysaccharides (LPS) are highly toxic components of the cell wall of Gram-negative bacteria and are often present in significant amounts in bacterial cell expression systems such as E.coli.

A number of methods have been adopted for the removal of endotoxin based on adsorption, in particular ion exchange chromatography. Although downstream processing can significantly reduce endotoxin levels in the product, efficient and cost effective removal of residual endotoxin from biopharmaceutical preparations remains a challenge.

Prometic has developed a novel affinity chromatography adsorbent, EtoxiClear, that is highly stable, robust and non-toxic, with a high affinity for bacterial endotoxin and low protein binding. EtoxiClear is a cost effective and scalable technology designed for use in endotoxin removal applications including process development, sample/buffer preparation and product polishing steps used during cGMP manufacture of biological molecules.

This application note describes the use of EtoxiClear to effectively remove endotoxin from a purified immunoglobulin protein solution at both bench scale and process scale; utilising PBL’s new 100 mm diameter Evolve Process Column.

MATERIALS & METHODS

A purified immunoglobulin solution (~12 mg/mL) was determined to have an endotoxin burden. As a result, both a 5 mL column and a 780 mL Evolve™ Process Column were packed with EtoxiClear™, using the guidelines in Table 1, to demonstrate high endotoxin clearance at different process scales. Prior to application the columns were depyrogenated for 16 hours using 0.5 M sodium hydroxide (NaOH). The NaOH was removed using ~1 column volume (CV) of water for injection (WFI) followed by equilibration buffer. Then 2 CV of the purified immunoglobulin solution was loaded onto each column and the non-bound fraction collected. 

RESULTS

CONCLUSIONS

EtoxiClear provides an immunoglobulin protein recovery of >96% for the 5 mL column (bench scale) and >99% recovery using the 780 mL column (100 mm diameter Evolve™ Process Column). There is a 3 log removal of endotoxin to obtain <1 EU/mL in the non-bound fraction, with less than 0.1 EU/mg protein for the Evolve™ Process Column.

As a result, EtoxiClear shows high performance and scalability for endotoxin clearance with low protein binding at both bench and process scale. The Evolve Process Column is well suited for EtoxiClear endotoxin removal applications and with the option to purchase a dedicated refresh kit to replace all the wetted parts of the column (including the acrylic tube), this column range provides significant cost savings whilst eliminating the need to prove endotoxin clearance from previous product and cleaning validation.

Click here to subscribe to our mailing list and ensure you always receive the latest updates and exclusive offers from Prometic Bioseparations.

SALES & TECHNICAL SUPPORT

Prometic Bioseparations Ltd
Horizon Park, Barton Road, Comberton
Cambridge, CB23 7AJ, UK.

Tel: +44 (0) 1223 420300
Email: sales-pbl@prometic.com
Web:  
www.prometic.com/bioseparations

EtoxiClear Prometic Bioseparations Ltd and the PBL logo are trademarks of Prometic Bioseparations Ltd. PuraBead® is registered with the U.S. Patent and Trademark Office.

PuraBead® - this product or portions thereof is manufactured and sold under licence from GE Healthcare under US patents 6841097 and 7341202 and any corresponding patents for life sciences research and the purification/separation of naturally occurring or recombinant plasma derived proteins.

Copyright © 2017 Prometic Bioseparations Ltd.

 

Previous Article
Evolve™ Process Column: Customer Evaluation
Evolve™ Process Column: Customer Evaluation

Next Article
EtoxiClear™: An novel affinity adsorbent for the efficient removal of endotoxin
EtoxiClear™: An novel affinity adsorbent for the efficient removal of endotoxin

A number of methods have been adopted for the removal of endotoxin based on adsorption, in particular ion-e...

×

Receive the latest updates straight to your inbox!

First Name
Last Name
!
Thank you!
Error - something went wrong!